Load balancing can be a tricky and confusing procedure to understand. As its name suggests, load balancing focuses on evenly distributing current draw throughout the entire rack. The goal is to achieve perfect balance so that more total current can be supplied to each branch circuit. 

Load Balancing 101

Did you know that load balancing has many of the same benefits as three phase PDUs? When a load is close to perfect balance, the current draw will be more evenly distributed down the three-phase line. The result of an even distribution is additional power headroom. Let's say that you have a 24A three-phase delta wired PDU that also has three branch circuits. If an 18A load is properly balanced, then 6A will be distributed to each branch, the current flowing for each of the input phase lines will be 10.4A, which means that the total current will be 31.2A. However, if the load wasn't properly balanced, then the three-phase lines might have 18A, 18A, and 0A to create a total current of 36A. In layman's terms, when the load is balanced across all three lines, more headroom is achieved.

It's important to note that load balancing can be a tricky process if you aren’t using the right tools. For example, IT devices often draw power in varying amounts based on their current consumption loads. In this vein, the anticipated power consumption for each device needs to be estimated so that the circuits will be evenly loaded. Additionally, devices that require two power supplies will further complicate the entire process, since multiple circuits will come into play. The good news is that Raritan's alternate circuit phase sequencing can reduce the complexity of the entire load balancing process. 

The Bottom Line: Raritan Can Simplify The Load Balancing Process

Raritan’s alternate circuit phase sequencing is uniquely designed so that you can more efficiently and easily complete load balancing tasks. Their approach simplifies the deployment of IT devices, while subsequently balancing three lines to provide greater power headroom. The Raritan solution also leverages a tracing power cord, which means that the likelihood of unplugging the incorrect device during regular maintenance is far less likely. In short, Raritan's load balancing solution helps you to increase headroom and ultimately lower downtime. 

To learn more about load balancing, click here.  
 

Other Blog Posts

Solving the Problem of the Data Center Digital Twin
Posted on July 11, 2024
2024 Will be a Big Year for Greater Analytics Automation in the Data Center. Here’s How
Posted on July 2, 2024
Who Should Care About ISO 27001?
Posted on July 1, 2024
Manage What You Measure: The Value of Legrand’s SmartSensor Portfolio
Posted on June 20, 2024
Data Centers are Getting Denser and Smarter: Here’s How Facility Managers Can Keep Up
Posted on May 28, 2024

View all Blog Posts

Subscribe

Upcoming Events

New Zealand Cloud & Datacenter Convention 2022
3 November 2022, 9am – 4pm  •  Grand Millennium Hotel, Auckland, New Zealand
Data Centre World Singapore
12th – 13th Oct 2022
Korea Cloud & Datacenter Convention 2022
6th Oct 2022
Philippines Cloud & Datacenter Convention 2022
4th Aug 2022
JANOG50 Meeting Hokkaido
3th – 15th July 2022

View all Events

Latest News

Legrand Certifications and Process Controls Provide Confidence in Information Security for Network-Connected Devices in Data-Related Applications
Posted on July 1, 2024
Legrand Revitalizes Data Center Sector with Two Revolutionary Intelligent Rack PDUs
Posted on May 1, 2023
Exclusive interview丨How does Huizhou upgrade its manufacturing industry?
Posted on December 2, 2021
Raritan Reveals The MasterConsole® Digital Dual KVM Switch
Posted on February 18, 2021
Legrand Data, Power and Control Division Announced as Finalist in Six Categories at DCS Awards 2020
Posted on November 9, 2020

View all news