The Advantages of Metering at the Inlet, Outlet, and Branch Circuits of Rack PDUs

Posted on March 13, 2015 by Gento

Raritan Power Distribution Unit

What are the features that separate Non-Intelligent from Intelligent Rack Power Distribution Units (iPDUs)?  There are literally dozens of them.  But, the single most important feature is metering.  Intelligent metering has become pivotal to data centers' understanding of how much power is being used at the device, rack, row, or facility level.  In turn, that information can helps data centers to become more energy efficient, increase uptime/availability, improve mean time to repair (MTTR), and do a better job at managing existing power capacity.  So, let's explore some of the benefits of intelligent metering at the inlet, outlet, and rack PDU branch circuit level. 

Red Power Distribution Unit

Metering at the Inlet

Metering at the inlet helps users to determine power usage and available capacity at the rack, which in turn, makes it easier to provision equipment. By metering at the inlet-level, users can avoid overloading circuits, and more easily calculate efficien­cy metrics like Power Usage Effectiveness (PUE).

Metering at the Outlet

Like metered inlet PDUs, outlet-metered models help users to determine power usage and available capacity at the rack, which in turn, makes it easier to provision equipment. Most importantly, outlet-level metering allows users to understand power consumption at the device or server-level in order to identify ghost servers, find underutilized servers, and allocate costs to specific business units or customers. It also allows data center managers to compare the efficiencies of IT.

Metering at the Rack PDU Branch Circuit

Metering at the Rack PDU branch circuit provides early warning if a circuit is becoming heavily loaded and runs the risk of tripping. Typically users receive an alert based on a pre-existing threshold that informs them when power demands need to be reduced.   Branch circuit metering is important because it allows users to add new devices to the cabinet or rack without having to worry about tripping the circuit breaker. It is particularly important when dealing with high-power consumption devices such as blade servers, because higher draws create an even greater chance of tripping a breaker and experiencing unplanned downtime.

Circuit Breaker Monitoring in the Rack PDU

Monitoring the circuit breaker allows users to know when and where a circuit breaker trips so that it can quickly be reset.

 

Click here to learn how eBay, one of the world's largest online commerce sites, uses intelligent PDU metering to slash power costs and increase compute performance. 

Other Blog Posts

了解人工智能时代的Neocloud基础设施
Posted on June 1, 2026
不被定义:看专业的传感技术如何改变数据中心冷却方式
Posted on June 1, 2026
通用输入:通过通用输入为数据中心提供无缝即插即用的灵活性
Posted on March 1, 2026
智能PDU:人工智能数据中心电源管理的关键组件
Posted on December 17, 2025
远程医疗影像扫描(远程超声/远程影像诊断/远程会诊系统)如何优化医院运营流程并提升患者满意度
Posted on November 24, 2025

View all Blog Posts

力登官方微信公众号
cn-blogfollow

近期活动

Japan Cloud & Datacenter Convention 2025
06 Jun 2025  •  Tokyo, Japan
Interop Tokyo 2025
11 Jun - 13 Jun 2025  •  Chiba, Japan
Suntelephone ICT Business Solution 2025 (Sendai)
17 Jun 2025  •  Sendai, Japan
Suntelephone ICT Business Solution 2025 (Kanazawa)
25 Jun 2025  •  Kanazawa, Japan
Suntelephone ICT Business Solution 2025 (Takamatsu)
04 Jul 2025  •  Takamatsu, Japan

View all Events

力登最新新闻

罗格朗推出新一代KVM平台,旨在数分钟内让关键系统恢复在线
Posted on October 22, 2026
罗格朗获得的行业认证和严格控制的生产流程,增强了数据中心运营中连网设备的稳定性。
Posted on July 1, 2024
重振数据中心行业——罗格朗重磅推出两款新的智能机架式PDU产品!
Posted on May 1, 2023
独家专访丨惠州如何升级制造业?法资企业CEO提了个建议
Posted on December 2, 2021
力登公司推出MasterConsole®数字双显示器KVM切换器
Posted on February 18, 2021

View all news