Environment Sensors

Environmental sensors to help data center managers understand hot spots, efficiently and optimally cool equipment and manage the risks associated with static electricity.

Our Sensors

DPX-T1

DPX-T1

Single temperature sensor with 10ft (3m) cable and RJ-12 connector.

DPX-T1H1

DPX-T1H1

Single combination temperature and humidity sensor with 10ft (3m) cable and RJ-12 connector.

DPX3-T1H1

DPX3-T1H1

Single combo temperature and humidity sensor, field replaceable sensor modules, RJ-45 connector (Not supported by DPX and PX models.)


DPX-T2H2

DPX-T2H2

Dual combination temperature and humidity sensors with 10ft (3m) cable from the RJ-12 connector to the first sensor and another 10ft (3m) of cable from the first sensor to the second sensor.

DPX3-T2H2-KIT

DPX3-T2H2-KIT

Two single combo temperature and humidity sensors, field replaceable modules, 10ft (3m) cable, RJ-45 connector

DPX-T3H1

DPX-T3H1

Three temperature sensors, middle sensor supporting humidity (four sensors total in three housings), 13ft (4m) cable from RJ-12 connector to first sensor, 3ft (1m) between first and second and second and third sensor housings.


DPX2-T3H1

DPX2-T3H1

Three temperature sensors, middle sensor supporting humidity (four sensors total in three housings),field replaceable sensor modules, 10ft (3m) cable from RJ-12 connector to first sensor, 3ft (1m) between first and second and second and third sensor housings (Not supported by DPX and PX models.)

DPX-AF1

DPX-AF1

Single airflow sensor with 10ft (3m) cable and RJ-12 connector. It is designed to monitor airflow such as cooling air blowing through a perforated tile.

DPX-T1DP1

DPX-T1DP1

Differential air pressure sensor with 10ft (3m) cable and RJ-12 connector. It is designed to monitor two air pressures such as the air pressure on either side of a thermal curtain separating a cold aisle from a hot aisle or above and below a raised floor or overhead plenum.


DPX-CC2-TR

DPX-CC2-TR

Dual contact closure sensor for use with third-party normally closed (NC) or normally open (NO) switches such as door open or closed, door locked or unlocked, smoke present or absent, etc.

DPX-WSF-KIT

DPX-WSF-KIT

Floor water (leak) sensor and a contact closure sensor for detecting water or water and glycol leaks. Reliably warns of water leaks at critical points below a raised floor.

DPX-WSC-35-KIT

DPX-WSC-35-KIT

11.5ft (3.5m) rope water (leak) sensor and a contact closure sensor for detecting water or water and glycol leaks. Detect leaks easily anywhere along the length of this flexible cable. Wrap around a rack with in-row cooling.


DPX-WSC-70-KIT

DPX-WSC-70-KIT

23ft (7m) rope water (leak) sensor and a contact closure sensor for detecting water or water and glycol leaks. Detect leaks easily anywhere along the length of this flexible cable. Longer length allow you to wrap around a datacenter CRAC unit.

DPX-ENVHUB2

DPX-ENVHUB2

Two-port (1x2) hub to expand RJ-12 sensor ports, comes with mounting bracket and RJ-12-to-RJ-12 cable to connect to, and receive power from, PX and EMX products.

DPX3-ENVHUB4

DPX3-ENVHUB4

Four-port (1x4) hub to expand RJ-45 sensor ports, comes with mounting bracket.


DX-PD2C5

DX-PD2C5

Two active dry contacts powered by 12V to support door locks. Five digital Normally Closed (NC) or Normally Open (NO) contact closures which require customer-provided NC or NO switches, e.g. door open/close, smoke present/absent, etc. Each of the five ports (channels) can be independently set to NC or NO, factory default is NC, RJ-45 connector (Not supported by DPX, PX or PX2 models).

DX-VBR

DX-VBR

Vibration sensor which detects acceleration along three axes (x, y, z). RJ-45 connector.

DX-PIR

DX-PIR

Digital proximity sensor which detects motion around a cabinet, RJ-45 connector (Not supported by DPX, PX or PX2 models).