The Advantages of Metering at the Inlet, Outlet, and Branch Circuits of Rack PDUs

Posted on March 13, 2015 by Gento

Raritan Power Distribution Unit

What are the features that separate Non-Intelligent from Intelligent Rack Power Distribution Units (iPDUs)?  There are literally dozens of them.  But, the single most important feature is metering.  Intelligent metering has become pivotal to data centers' understanding of how much power is being used at the device, rack, row, or facility level.  In turn, that information can helps data centers to become more energy efficient, increase uptime/availability, improve mean time to repair (MTTR), and do a better job at managing existing power capacity.  So, let's explore some of the benefits of intelligent metering at the inlet, outlet, and rack PDU branch circuit level. 

Red Power Distribution Unit

Metering at the Inlet

Metering at the inlet helps users to determine power usage and available capacity at the rack, which in turn, makes it easier to provision equipment. By metering at the inlet-level, users can avoid overloading circuits, and more easily calculate efficien­cy metrics like Power Usage Effectiveness (PUE).

Metering at the Outlet

Like metered inlet PDUs, outlet-metered models help users to determine power usage and available capacity at the rack, which in turn, makes it easier to provision equipment. Most importantly, outlet-level metering allows users to understand power consumption at the device or server-level in order to identify ghost servers, find underutilized servers, and allocate costs to specific business units or customers. It also allows data center managers to compare the efficiencies of IT.

Metering at the Rack PDU Branch Circuit

Metering at the Rack PDU branch circuit provides early warning if a circuit is becoming heavily loaded and runs the risk of tripping. Typically users receive an alert based on a pre-existing threshold that informs them when power demands need to be reduced.   Branch circuit metering is important because it allows users to add new devices to the cabinet or rack without having to worry about tripping the circuit breaker. It is particularly important when dealing with high-power consumption devices such as blade servers, because higher draws create an even greater chance of tripping a breaker and experiencing unplanned downtime.

Circuit Breaker Monitoring in the Rack PDU

Monitoring the circuit breaker allows users to know when and where a circuit breaker trips so that it can quickly be reset.

 

Click here to learn how eBay, one of the world's largest online commerce sites, uses intelligent PDU metering to slash power costs and increase compute performance. 

Other Blog Posts

從資料中心失效對企業帶來的骨牌效應──探討感測器的重要性
Posted on November 5, 2023
更高規格的電源要求加速AI市場成長與Raritan PDU的採用
Posted on October 11, 2023
資料中心服務中斷次數減少,但停機的代價仍舊可觀
Posted on September 20, 2023
意見調查:資料中心面臨能源使用與人力短缺困境
Posted on September 20, 2023
Raritan安全切換器:相容於Secure NIAP 4.0的桌上型KVM
Posted on September 20, 2023

View all Blog Posts

訂閱

近期活動

New Zealand Cloud & Datacenter Convention 2022
3 November 2022, 9am – 4pm  •  Grand Millennium Hotel, Auckland, New Zealand
Data Centre World Singapore
12th – 13th Oct 2022
Korea Cloud & Datacenter Convention 2022
6th Oct 2022
Philippines Cloud & Datacenter Convention 2022
4th Aug 2022
JANOG50 Meeting Hokkaido
3th – 15th July 2022

View all Events

Raritan最新新聞

Legrand 使用兩大創新智慧型機架 PDU 重新活化資料中心產業
Posted on May 1, 2023
Exclusive interview丨How does Huizhou upgrade its manufacturing industry?
Posted on December 2, 2021
Raritan 發表 MasterConsole® 數位雙電腦切換器
Posted on February 18, 2021
Legrand Data, Power and Control Division Announced as Finalist in Six Categories at DCS Awards 2020
Posted on November 9, 2020
Raritan 新款智慧機櫃控制器 (SRC) 可智慧管理資料中心與關鍵任務設施的環境與安全性資訊
Posted on November 9, 2020

View all news