New ASHRAE Study Will Encourage Data Centers to Operate at a Lower Relative Humidity

Posted on April 8, 2015 by Gento

For the last several years, ASHRAE has been advocating that data centers allow temperatures to rise in order to save money on cooling resources.  Now, an upcoming study will assert that data centers save even further by allowing humidity to drop to an RH of 8 percent.

In a recent interview with Data Center Dynamics, Dan Beaty, Cofounder of ASHRAE’s TC 9.9 said, “We ran a test with different types of floor tiles and clothing, and we found that between eight percent and 20-25 percent, the difference in static electricity is insignificant.”

The finding could lead to significant operational cost savings.  According to EnergyStar.Gov[1]:

A typical data center uses a great deal of energy maintaining humidity through multiple CRAC units. Each CRAC unit has the ability to humidify, de-humidify, heat and cool. When humidity gets too low, a typical CRAC unit will raise the humidity by using inefficient infrared or steam canister humidifiers. These humidifiers can use an order of magnitude more energy than adiabatic humidifiers (e.g., an ultrasonic humidifier) and can also raise the temperature of the data center because they produce heat to generate steam.

Moving forward, data centers can meet ASHRAE’s updated recommendations for temperature and humidity by using environmental sensors along with DCIM software.  Sensors are an inexpensive, easy-to-deploy technology that makes it easier for facilities managers to monitor rows and racks and adjust CRAC and CRAHs to make optimal use of cooling resources.

The data can be plotted on a psychrometric chart to allow users to easily compare the real-time temperature and humidity data collected from environmental sensors in cabinets against the environmental envelope of target operating zones displayed on a psychrometric chart, ensuring optimal conditions for the operation of critical IT systems in compliance with the new ASHRAE guidelines.


Want to improve your data center environment managment? Read our white paper, "Environmental Data Center Management and Monitoring" to learn whether you're already on the right path and whether there's room for improvement. 


[1] http://www.energystar.gov/index.cfm?c=power_mgt.datacenter_efficiency_inlet_temp

Other Blog Posts

從資料中心失效對企業帶來的骨牌效應──探討感測器的重要性
Posted on November 5, 2023
更高規格的電源要求加速AI市場成長與Raritan PDU的採用
Posted on October 11, 2023
資料中心服務中斷次數減少,但停機的代價仍舊可觀
Posted on September 20, 2023
意見調查:資料中心面臨能源使用與人力短缺困境
Posted on September 20, 2023
Raritan安全切換器:相容於Secure NIAP 4.0的桌上型KVM
Posted on September 20, 2023

View all Blog Posts

訂閱

近期活動

New Zealand Cloud & Datacenter Convention 2022
3 November 2022, 9am – 4pm  •  Grand Millennium Hotel, Auckland, New Zealand
Data Centre World Singapore
12th – 13th Oct 2022
Korea Cloud & Datacenter Convention 2022
6th Oct 2022
Philippines Cloud & Datacenter Convention 2022
4th Aug 2022
JANOG50 Meeting Hokkaido
3th – 15th July 2022

View all Events

Raritan最新新聞

Legrand 使用兩大創新智慧型機架 PDU 重新活化資料中心產業
Posted on May 1, 2023
Exclusive interview丨How does Huizhou upgrade its manufacturing industry?
Posted on December 2, 2021
Raritan 發表 MasterConsole® 數位雙電腦切換器
Posted on February 18, 2021
Legrand Data, Power and Control Division Announced as Finalist in Six Categories at DCS Awards 2020
Posted on November 9, 2020
Raritan 新款智慧機櫃控制器 (SRC) 可智慧管理資料中心與關鍵任務設施的環境與安全性資訊
Posted on November 9, 2020

View all news