Load Balancing: What Is It?

Posted on April 25, 2019 by Gento

Load balancing can be a tricky and confusing procedure to understand. As its name suggests, load balancing focuses on evenly distributing current draw throughout the entire rack. The goal is to achieve perfect balance so that more total current can be supplied to each branch circuit. 

Load Balancing 101

Did you know that load balancing has many of the same benefits as three phase PDUs? When a load is close to perfect balance, the current draw will be more evenly distributed down the three-phase line. The result of an even distribution is additional power headroom. Let's say that you have a 24A three-phase delta wired PDU that also has three branch circuits. If an 18A load is properly balanced, then 6A will be distributed to each branch, the current flowing for each of the input phase lines will be 10.4A, which means that the total current will be 31.2A. However, if the load wasn't properly balanced, then the three-phase lines might have 18A, 18A, and 0A to create a total current of 36A. In layman's terms, when the load is balanced across all three lines, more headroom is achieved.

It's important to note that load balancing can be a tricky process if you aren’t using the right tools. For example, IT devices often draw power in varying amounts based on their current consumption loads. In this vein, the anticipated power consumption for each device needs to be estimated so that the circuits will be evenly loaded. Additionally, devices that require two power supplies will further complicate the entire process, since multiple circuits will come into play. The good news is that Raritan's alternate circuit phase sequencing can reduce the complexity of the entire load balancing process. 

The Bottom Line: Raritan Can Simplify The Load Balancing Process

Raritan’s alternate circuit phase sequencing is uniquely designed so that you can more efficiently and easily complete load balancing tasks. Their approach simplifies the deployment of IT devices, while subsequently balancing three lines to provide greater power headroom. The Raritan solution also leverages a tracing power cord, which means that the likelihood of unplugging the incorrect device during regular maintenance is far less likely. In short, Raritan's load balancing solution helps you to increase headroom and ultimately lower downtime. 

To learn more about load balancing, click here.  
 

Other Blog Posts

從資料中心失效對企業帶來的骨牌效應──探討感測器的重要性
Posted on November 5, 2023
更高規格的電源要求加速AI市場成長與Raritan PDU的採用
Posted on October 11, 2023
資料中心服務中斷次數減少,但停機的代價仍舊可觀
Posted on September 20, 2023
意見調查:資料中心面臨能源使用與人力短缺困境
Posted on September 20, 2023
Raritan安全切換器:相容於Secure NIAP 4.0的桌上型KVM
Posted on September 20, 2023

View all Blog Posts

訂閱

近期活動

New Zealand Cloud & Datacenter Convention 2022
3 November 2022, 9am – 4pm  •  Grand Millennium Hotel, Auckland, New Zealand
Data Centre World Singapore
12th – 13th Oct 2022
Korea Cloud & Datacenter Convention 2022
6th Oct 2022
Philippines Cloud & Datacenter Convention 2022
4th Aug 2022
JANOG50 Meeting Hokkaido
3th – 15th July 2022

View all Events

Raritan最新新聞

Legrand 使用兩大創新智慧型機架 PDU 重新活化資料中心產業
Posted on May 1, 2023
Exclusive interview丨How does Huizhou upgrade its manufacturing industry?
Posted on December 2, 2021
Raritan 發表 MasterConsole® 數位雙電腦切換器
Posted on February 18, 2021
Legrand Data, Power and Control Division Announced as Finalist in Six Categories at DCS Awards 2020
Posted on November 9, 2020
Raritan 新款智慧機櫃控制器 (SRC) 可智慧管理資料中心與關鍵任務設施的環境與安全性資訊
Posted on November 9, 2020

View all news