Are Data Center Power and Cooling Being Overlooked?

Posted on February 10, 2016 by Gento

There’s been no shortage of coverage on the data center industry over the last few years.  Topics like big data, cloud, CI, IOT, HPC, and virtualization get all the headlines. But why don’t fundamental topics - like power, cooling, and infrastructure - get the same amount of exposure?

Last year, Lenny Liebmann wrote in a piece for BizTech Magazine:

“With all of the attention being paid to the cloud, Big Data, mobility and other hot-button IT issues, it’s easy to forget about seemingly mundane concerns such as data center power and cooling. 

But IT decision-makers do so at their own peril, because the transformations taking place in the data center are making it essential for IT departments to change the way they manage power and cooling. And any failure to make those changes can leave organizations unacceptably vulnerable to power outages, overheated equipment and excessive utility bills.”

So there we have it. At a time when so much has been made of advances in computing, storage, and networking, it’s easy to overlook the underlying infrastructure that makes it possible and reliable.  Read more of Liebmann’s article in the latest edition of the Hot Aisle.

But consider how a leading company like eBay approaches infrastructure in its Tier IV Topaz Data Center:

“With multiple blade servers deployed in certain cabinets, eBay wanted any given rack to be capable of provisioning loads up to 17kW. While this is achievable with traditional 208V distribution, Topaz enjoys significant cost efficiencies by extending higher- voltage distribution all the way to each cabinet. By supplying 400V power to each rack, eBay minimizes step-down transformation and line transmission loss while simultaneously reducing copper utilization.  Specifically, eBay provides 400V 3-phase power to two Raritan intelligent rack power distribution units in each cabinet.

The rack PDU, with internal line-to-neutral (3-phase WYE) wiring, supplies each server with 240V, single-phase power – well within the operating range of the power supplies of virtually any IT equipment.  By eliminating unnecessary voltage transformations, 400V power reduces energy costs by approximately 2-3% vs. 208V distribution; and approximately 4-5% vs. 120V distribution.”

One might argue that few companies in the world have the resource demands of an eBay.  But, with emerging trends changing the physical make up of data centers all over – it would be wise to start taking power and cooling more seriously. 


Learn more about Raritan rack power distribution and environmental monitoring solutions. 

Other Blog Posts

從資料中心失效對企業帶來的骨牌效應──探討感測器的重要性
Posted on November 5, 2023
更高規格的電源要求加速AI市場成長與Raritan PDU的採用
Posted on October 11, 2023
資料中心服務中斷次數減少,但停機的代價仍舊可觀
Posted on September 20, 2023
意見調查:資料中心面臨能源使用與人力短缺困境
Posted on September 20, 2023
Raritan安全切換器:相容於Secure NIAP 4.0的桌上型KVM
Posted on September 20, 2023

View all Blog Posts

訂閱

近期活動

New Zealand Cloud & Datacenter Convention 2022
3 November 2022, 9am – 4pm  •  Grand Millennium Hotel, Auckland, New Zealand
Data Centre World Singapore
12th – 13th Oct 2022
Korea Cloud & Datacenter Convention 2022
6th Oct 2022
Philippines Cloud & Datacenter Convention 2022
4th Aug 2022
JANOG50 Meeting Hokkaido
3th – 15th July 2022

View all Events

Raritan最新新聞

Legrand 使用兩大創新智慧型機架 PDU 重新活化資料中心產業
Posted on May 1, 2023
Exclusive interview丨How does Huizhou upgrade its manufacturing industry?
Posted on December 2, 2021
Raritan 發表 MasterConsole® 數位雙電腦切換器
Posted on February 18, 2021
Legrand Data, Power and Control Division Announced as Finalist in Six Categories at DCS Awards 2020
Posted on November 9, 2020
Raritan 新款智慧機櫃控制器 (SRC) 可智慧管理資料中心與關鍵任務設施的環境與安全性資訊
Posted on November 9, 2020

View all news